Glasswool - Mineral Plus Rainscreen Insulation

Application
Benefits
- High thermal performance
- Sound absorbing
- Fire protection
- Slab format - easy to install
- Silicone treated - water resistant
- High tear resistance fabric
Product Description
Mineral Plus is a high density silicone treated glasswool with a black textile facing, suitable for the external insulation of buildings. Mineral Plus is a non-combustible, moisture resistant, vapour permeable insulation that combines a high thermal performance with exceptional acoustic properties.
Mineral Plus comes in conveniently sized slabs making it quick and safe to install. The product is made using up to 80% recycled glass and with ECOSE® Technology, a revolutionary bio-based binder that contains no added formaldehyde, meeting the highest environmental requirements.
Suitability of Use
In accordance with C/AS2, 1st edition 2019, Mineral Plus is suitable as a substantive component in external wall cladding systems. Mineral Plus comprises a surface finish fabric applied directly to a non-combustible substrate in accordance with C/AS2 Part 5.8.2.a.
With a robust woven glass textile and silicone treatment, Mineral Plus is designed to withstand intermediate weathering from moisture.
Type
Product Type | Slab |
Facing Type | Woven Glass Faced |
Use
Renovation or New Building | Renovation & New Building |
Building Type | Residential & Commercial |
Product Range
Specifications
Thermal Resistance (m²K/W at 15°C) | Thickness (mm) | Width (mm) | Length (mm) |
---|---|---|---|
1.5 | 50 | 600 | 1200 |
2.3 | 75 | 600 | 1200 |
Technical
Technical Information
Symbol | Result | Unit of measure | Standard | |
---|---|---|---|---|
Thermal conductivity | λD | 0.033 | W/mK | AS/NZS 4859.1 |
Fire Hazard Properties | Fire hazard properties: 0, 0, 0, 2. | AS/NZS 1530.3 | ||
Combustibility | Non-combustible | AS 1530.1 | ||
Reaction to fire | Euroclass A1 | EN 13 501-1 | ||
Short term water absorption | WS | < 1 | kg / m² | EN 1609 |
Long term water absorption | WL(P) | < 3 | kg / m² | EN 12087 |
Air-flow resitivity | AFr | < 5 | kPa·s / m² | EN 29053 |
Water vapour transmission rate | µ | 1 | - | EN 12086 |